Most commercial standby generators in Horry County run a scheduled exercise once a week, for 10 to 20 minutes. The rest of the week, the only thing watching the unit is its own controller, and a controller can log a fault that nobody reads until the power goes out.
Cooper Electrical Services provides commercial generator monitoring for businesses in Myrtle Beach, Horry County, and northern Georgetown County. Every commercial generator we monitor reports to one dashboard, with alarms monitored 24/7 by our service team, not by an app that someone at your facility has to remember to check. As the only family owned unlimited license electrical contractor in Myrtle Beach, we handle the monitoring, the notifications, and the service call with our own factory certified technicians. No subcontractors.
How Cooper-Monitored Service Works
It is an annual subscription. Commercial generator monitoring from Cooper is an annual subscription service, included in many of our service agreements.
We install and integrate the RTU. A Cooper technician installs a remote terminal unit (RTU) at your generator and integrates it with the generator and transfer switch controls. The RTU works with any generator brand and reports over 4G cellular service, so it does not depend on your building's network or internet connection. Call with the make and model and we'll tell you what the installation takes for your unit.
We set the alarms and the notification list. The RTU carries 16 alarm points, among them utility power failure, generator running, generator under load, transfer switch position, system not in auto, common alarm, shutdown, battery charger failure, low DC voltage, low oil pressure, high engine temperature, and low fuel. Cooper configures the points that apply to your unit and who hears about each one, by text message, by email, or both: HOA property managers, facility managers, business owners, maintenance contacts. Our service team is on the list for every generator we monitor.
Alarms are monitored 24/7. Every commercial generator we monitor reports to the same dashboard, and every alarm reaches Cooper's service team the moment it comes in, day or night. We see whether each unit ran, whether it tested, and what alarms came in.
Alarms dispatch a technician. When an alarm calls for a technician, dispatch is automatic. You don't have to call it in. You hear from us with what the log shows and what we recommend: a scheduled visit, an emergency repair, or nothing yet.
The record is there when you need it. Every run, test, alarm, and service visit is time-stamped in the portal. If an insurer, a fire marshal, or an accrediting body asks whether the generator has been testing, we pull the history for your unit.
What The Log Looks Like
Three events from Cooper's own monitoring history, with the site names removed.
- A weekly exercise with load transfer. 8:17:10 a.m., Generator Running. 8:17:24, Generator Under Load. 8:32:15, off load. 8:37:20, All Systems Normal. That is 20 minutes, logged every Wednesday. If a week goes by without that entry, Cooper sees it.
- A utility outage. 8:53:43 a.m., Utility Power Failure. 8:53:49, Generator Running. 8:53:56, Generator Under Load. 9:14:23, All Systems Normal, after the transfer switch returned the building to utility power and the generator finished its cooldown. Nobody at the site had to report it.
- An annual service visit. 12:23:27 p.m., Generator Not In Auto, as the technician takes the unit out of automatic to work on it. 12:23:35, Generator Running, for the test run. 12:41:37, All Systems Normal, back in auto. The visit is time-stamped in the log, so you have a dated record that the work was done.
The battery charger alarm that comes in with an outage is expected. The charger runs on utility power, so it drops out when the utility does. The system also watches the charger's DC output separately, so a real charger problem shows up as a low DC voltage alarm while the power is on.
Generac, Kohler, And Cummins Monitoring
Generac, Kohler, and Cummins each offer their own remote monitoring platform, and Cooper can set up any of them on a commercial unit if your facility calls for it. For commercial generators, our recommendation is Cooper-monitored service, for three reasons. The RTU works across brands, so a multi-site operator with a Generac at one property and a Kohler at another sees both on one dashboard. Its 16 alarm points and notification lists are configured for each site. And Cooper has monitored commercial generators this way since 2018.
Who It's For
- Service agreement clients. Monitoring is part of many of our Commercial Generator Service Agreements, alongside quarterly inspections, annual service, NFPA 110 testing, and priority response.
- Existing generators. Any commercial standby generator in our service area, whether or not Cooper installed it.
- HOAs and managed properties. Communities and properties with a standby generator, with notifications set up for the property manager and whoever else the association names.
- Multi-site operators. Hospitality groups, medical practices, and retailers with locations across the Grand Strand get every generator on one dashboard, regardless of brand, watched by one service team.
NFPA 110 And Documentation
NFPA 110 calls for emergency power supply systems to be inspected weekly and exercised under load at least monthly, with the results recorded. Monitoring doesn't replace those inspections. It does give Cooper a dated record of every run, test, and alarm on your unit, which is what an insurer, a fire marshal, or an accrediting body asks for. Facilities that also need annual full-load verification can pair monitoring with our load bank testing.
Why Choose Cooper Electrical Services For Generator Monitoring
- The dashboard is watched by a service company, not an inbox. Our own factory certified technicians respond — no subcontractors.
- 24/7 alarm monitoring with automatic technician dispatch.
- The only family owned unlimited license electrical contractor in Myrtle Beach, backed by the Cooper family's 35+ years in Horry County.
- Factory certified on Generac, Kohler, and Cummins.
- Integrated with our Commercial Generator Service Agreements, load bank testing, and the fuel delivery program for agreement clients.
- Local to the Grand Strand's weather, codes, and coastal conditions.
We monitor commercial generators throughout Myrtle Beach, North Myrtle Beach, Conway, Little River, Loris, Carolina Forest, Pawleys Island, Murrells Inlet, and all of Horry County.
Homeowner? See remote monitoring for residential generators.
Frequently Asked Questions
Can you monitor a generator Cooper didn't install?
Yes. We monitor commercial standby generators regardless of who installed them or what brand they are. Call with the make and model and we'll confirm what the installation takes for your unit.
What does Cooper actually see?
Every alarm, run, and exercise test on your generator, time-stamped, on the same dashboard that carries every commercial generator we monitor. An outage on the dashboard can be cross-referenced against our service calls.
Will our own people get the alerts?
Yes. Each alarm can go by text message, email, or both to the people you name, whether that's a property manager, a facility manager, or the owner, alongside Cooper's service team.
Does the system need our network or Wi-Fi?
No. The RTU reports over 4G cellular service, so it keeps reporting when your building's internet goes down with the power.
What happens when an alert comes in after hours?
Alarms are monitored 24/7, and when one calls for a technician, dispatch is automatic.
Does monitoring replace our monthly exercise and inspections?
No. NFPA 110 inspections and exercise still have to happen, and so does scheduled maintenance. Monitoring tells us when something changed between visits.
Add Your Generator To Cooper-Monitored Service
Call (843) 945-1627 to add your commercial generator to Cooper-monitored service, or to ask whether your unit can be connected. If you're not sure what you have, give us the make and model and we'll take it from there. No-pressure assessment.
Questions or concerns?
We’re committed to fast, dependable, professional customer service. Reach out today to learn more about commercial generator monitoring.